Skip links

Suction Scanner self cleaning filter SCRO & SCRL DW

Suction Scanner self cleaning filter SCRO & SCRL DW

SUCTION SCANNER SELF CLEANING FILTER ASI316 (MEDIUM, BIG FLOW RATE)
MAIN TECHNICAL FEATURES:
  • Flow-rate uninterrupted even during washing phase
  • Filtration degree from 2000 to 25 μm on polyester mesh/ AISI316
  • Maximum flow rate 1000 m3/h with a single filter
  • Minimum water for cleaning
APPLICATIONS:
  • Drinking water distribution systems
DM174/2004 Certificate for Contact with Potable Water

Download Datasheet

Description

HOW IT WORKS

Water enters the filter through the IN inlet and goes through the filtering cylinder (4) from the inside to the outside. This will retain all non-deformable suspended solids that are the same size or bigger than the filtration degree installed. Filtered water leaves through the outlet pipe (OUT).

REGENERATION

The continuous settling of suspended solids inside the filtering cylinder (4) obstructs the passage of water which results in a pressure difference (∆P). At a pre-set value of ∆P (range 0.3 ÷ 1 Bar) an automatic cycle will start to clean the filter cylinder (4). This operation begins with a signal that opens the discharge valve (3) and creates communication between the suction nozzles (1) with the outside environment. At the same time, the electric motor (5) creates a rotating motion which enables the nozzles to inspect the filtering surface. Dirt is ejected through the discharge valve (3). The cleaning cycle lasts approximately 15 seconds. The SCRO version is equipped with a manual safety pre-filter with a 3 mm filtration rating.

CONTROL

A switchboard controls the washing phases. The signal that starts the cleaning cycle is given by a differential pressure switch or by time.
The switchboard gives an “alarm” signal in case of problems in the washing system.
These signals can be sent to a pre-existing control centre. The washing phase can also be controlled manually. The solenoid controlling the valve is pneumatic.

FILTER ELEMENT SECTION AND CLEANING SYSTEM

TECHNICAL DATA AND DIMENSIONS | SCR L DW

MODELSCR L 10SCR L 15SCR L 30SCR L 45SCR L 60SCR L 75SCR L 90SCR L 130
Filtering Area (cm²)100015003000450060007500900013000
Connections- In/Out2"3"DN100DN150DN200DN250DN300DN350
Exhaust connections1" F1" F1"1/2 F1"1/2 F1"1/2 F1"1/2 F1" F2" F
Draining connections1/2" F1/2" F1/2" F1/2" F1/2" F1" F1" F1" F
1 Bar washing flow rate with mesh from 500 to 25 micron – m³/h2347991515
Wash duration - Sec1515151515151515
Min-max pressure – Bar0,5-100,5-100,5-100,5-100,5-100,5-100,5-100,5-10
Max Temperature - °C4040404040404040
Power supply – Volt400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz
Power required – Watt9090180180180370370550
Solenoid valve – Volt / Watt24 AC / 624 AC / 624 AC / 624 AC / 624 AC / 624 AC / 624 AC / 624 AC / 6
Pneumatic supply - Bar2-82-82-82-82-82-82-82-8
Construction certificatesCECECECECECECECE
*Maximum size of inlet particles – mm33333333
Max total suspended solids at inlet 125 micron – mg/l100100100100100100100100
A (mm)757903107113091755202725813181
B (mm)470485607635706791969969
C (mm)327327423423516714852852
D (mm) Cartridge extraction485485685685853113011601160
WEIGHT when empty Kg28345162115208285450
WEIGHT in operation Kg36427086133202346598

TECHNICAL DATA AND DIMENSIONS | SCR O DW

MODELLOSCRO 10SCRO 15SCRO 30SCRO 45SCRO 60SCRO 75SCRO 90SCRO 130
Filtering area (cm²)100015003000450060007500900013000
Connections- In/Out2"3"DN100DN150DN200DN250DN300DN350
Exhaust connections1"1/2 F1"1/2 F2" F2" F2" F2" F2" F2" F
Draining connections1/4" F1/4" F1/4" F1/4" F1/4" F1" F1" F1" F
1 Bar washing flow rate with mesh from 500 to 25 micron – m³/h234911111515
Wash duration – Sec.1515151515151515
Min-max pressure – Bar0,5-100,5-100,5-100,5-100,5-100,5-100,5-100,5-10
Max Temperature - °C4040404040404040
Power supply – Volt400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz400 50/60 Hz
Power required – Watt9090180180180370370550
Solenoid valve – Volt / Watt24 AC / 624 AC / 624 AC / 624 AC / 624 AC / 624 AC / 624 AC / 624 AC / 6
Pneumatic supply – Bar2-82-82-82-82-82-82-82-8
Construction certificatesCECECECECECECECE
Maximum size of inlet particles* – mm33333333
Max total suspended solids at inlet 125 micron – mg/l100100100100100100100100
A (mm)9001045143016751920210022052576
B (mm)4154155405405406309401114
C (mm)330410410430460634678700
D (mm) Cartridge extraction4505706408851130113011601690
WEIGHT when empty Kg37556781125220335450
WEIGHT in operation Kg3891105114152222370633

PARTS DESCRIPTION

PART DESCRIPTION
Body AISI316 – SAF2205
Cover AISI316 – SAF2205
Connection threading BSP
Conncion flanges EN 1092-1 PN10
Mesh support strainer PVC – AISI316
Filtering mesh Polyester – AISI316: 500, 300, 200, 125, 80, 50, 25 µm
Protection mesh PE
Suction nozzle PE
Nozzle support POM – AISI316 – SAF2205
Nozzle pipe PVC – AISI316 – SAF2205
Internal seals EPDM
Reduction unit Aluminium and carbon steel
Electric motor Hot-painted aluminium
Solenoid valve Three-way aluminium
Switchboard ABS IP55 with front display
Differential pressure switch Aluminium with parts in contact with liquid made of AISI 316
Discharge valve PP diaphragm with flow rate regulation
Pressure gauges Stainless steel with 2″1/2 dial, radial connection and 0-10 Bar indication

FILTERING MESH FLOW RATE TABLE FOR SCR O & L FILTERS (m3/h)

MODEL 500 μm PES AISI316 300 μm PES AISI316 200 μm PES AISI316 120 μm PES AISI316 80 μm PES AISI316 50 μm PES AISI316 25 μm PES AISI31
SCR 2-10 50 50 50 50 37 26 13
SCR 3-15 80 80 80 80 55 40 19
SCR 100-30 140 140 140 140 95 70 34
SCR 150-45 205 205 205 205 145 103 51
SCR 200-60 275 275 275 275 193 138 69
SCR 250-75 360 360 360 360 250 180 90
SCR 300-90 685 685 630 480 319 228 114
SCR 350-130 1030 1030 1030 685 480 340 171

SUGGESTED INTALLATION

Additional information

Applicazione

Scopri
Drag